Electromagnetic compatibility (EMC) describes the ability of a product to operate reliable in an electromagnetic environment without affecting it with unwanted electromagnetic phenomena.
We are accredited by the > DAkkS and recognized by the IECEE in the > CB Scheme. In addition, we are a member of the > Third Party Test Data Program of Unterwriters Laboratories (UL).
As > designated technical service (category A, B und D) of the Kraftfahrt-Bundesamtes (KBA) we ware authorized to carry out EMC tests for EC type-approvals, UN ECE licenses and national road traffic regulations.
​
We support you in the creation of a test plan tailored to your requirements, both for normative tests and for development tests. Please introduce us to your product.
EMC Services
We investigate the electromagnetic compatibility of assemblies, devices and systems for use in the medical, automotive, railway, industrial and laboratory sectors. In our anechoic chambers (3 m / 10 m working section), we can test both small and larger products with a weight of up to 3 t.
​
-
Tests and approval service for the motor vehicle directive (E-mark)
-
EMC tests for the aviation sector (DO-160 section 21)
Emission Testing
-
Conducted Disturbance (1-phase, 3-phase, 25 A) 9 kHz - 30 MHz
-
Radiated Disturbance in 3 - 10 m distance (150 kHz - 18 GHz)
-
Low Frequency (electrical- und magnetic field 5 Hz - 30 kHz)
-
Disturbance Power (30 MHz - 300 MHz)
-
Main Voltage Phenomena (harmonic and flicker) 1-phase, 16 A
-
Safety measurement in electromagnetic fields and environmental tests
Immunity Testing
-
ESD-Generation 25 kV
-
RF Fields more than 100 V/m between 150 kHz and 18 GHz
-
Fast Transients (Burst) 4 kV
-
High Power Transients (Surge) 4 kV; 1,2/50 µs
-
Vehicle on board electrical transient and harmonic disturbances
-
Induced RF Currents (U0 = 30 V)
-
Power Frequency Magnetic Fields 160 A/m
-
Pulse Magnetic Fields Immunity 1400 A/m
-
Voltage Dips Interrupts and Fluctuations on AC and DC Supply Systems
​
​
Special Environment
-
Anechoic chamber (18 m x 13 m x 9 m; 3 t/m²)
-
Anechoic chamber (5 m x 4 m x 3,5 m; 5 t/m²)
-
Anechoic chamber (5 m x 5 m x 2,5 m)
Auswahl an Grundnormen
-
IEC 61000-4-2
-
IEC 61000-4-3
-
IEC 61000-4-4
-
IEC 61000-4-5
-
IEC 61000-4-6
-
IEC 61000-4-8
-
IEC 61000-4-11​
-
IEC 61000-4-12
-
IEC 61000-4-16
​​
-
IEC 61000-4-18
-
IEC 61000-4-29​
-
IEC 61000-4-30
Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Electrical fast transient/burst immunity test
Surge immunity test
Immunity to conducted disturbances, induced by radio-frequency fields
Power frequency magnetic field immunity test
Voltage dips, short interruptions and voltage variations immunity tests
Ring wave immunity test
Test for immunity to conducted, common mode disturbances in the
frequency range 0 Hz to 150 kHz
Damped oscillatory wave immunity test
Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
Power quality measurement methods
Some product standards
-
IEC 60601-1-2
-
EN 50155
-
RTCA DO-160
-
IEC 60945
-
CISPR 25
​​
-
ECE-R 10
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests
Railway applications - Electronic equipment used on rolling stock
Department of defense – Test method standard for environmental engineering considerations
Environmental Conditions and Test Procedures for Airborne Equipment
Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility
​